DC/DC Converter
THN 20 Series, 20 Watt
•
Smallest encapsulated 20 W Converter!
Ultra compact size: 1.0" x 1.0" x 0.4"
•
Shielded metal case with isolated
baseplate
•
•
•
•
•
Wide 2:1 input voltage ranges
•
•
I/O isolation voltage 1500 VDC
•
3-year product warranty
Very high efficiency up to 90%
UL 62368-1 IEC 62368-1
Output voltage adjustable
Remote On/Off control
Operating temp. range –40°C to +75°C
and up to 85 °C with heat-sink
Input filter meets EN 55022 class A
without external components
The THN 20 series is the latest generation of high performance DC/DC converter modules with highest power density. The product achieves 20 W output
power while it comes in a metal case with dimensions of only 1.0" x 1.0" x
0.4". All models have a wide 2:1 input voltage range and precisely regulated
output voltages, even under no load conditions. Highest efficiency of up to
90% makes this product very reliable and applicable in temperature ranges of
up to 75°C or 85°C with optional mounted heat sink. Together with low input
current characteristics at minimal load and remote On/Off control these converters are the ideal solution for battery-operated systems. Typical applications
are in mobile equipment, instrumentation, distributed power architectures in
communication and industrial electronics and everywhere where space on the
PCB is critical.
Models
Order Code
Input Voltage
Range
THN 20-1210
THN 20-1211
THN 20-1212
THN 20-1213
THN 20-1222
THN 20-1223
THN 20-2410
THN 20-2411
THN 20-2412
THN 20-2413
THN 20-2422
THN 20-2423
THN 20-4810
THN 20-4811
THN 20-4812
THN 20-4813
THN 20-4822
THN 20-4823
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
4'500 mA
4'000 mA
1'670 mA
1'330 mA
833 mA
667 mA
4'500 mA
4'000 mA
1'670 mA
1'330 mA
833 mA
667 mA
4'500 mA
4'000 mA
1'670 mA
1'330 mA
833 mA
667 mA
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
833 mA
667 mA
–12 VDC
–15 VDC
833 mA
667 mA
–12 VDC
–15 VDC
833 mA
667 mA
typ.
89 %
89 %
89 %
89 %
89 %
90 %
90 %
91 %
90 %
91 %
90 %
90 %
90 %
90 %
90 %
90 %
89 %
90 %
Options
THN-HS1
- Optional Heat Sink: www.tracopower.com/products/thn-hs1.pdf
www.tracopower.com
September 20, 2023
Page 1 / 5
THN 20 Series, 20 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
- At full load
24 Vin models:
48 Vin models:
Surge Voltage
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
10 mA typ.
6 mA typ.
4 mA typ.
1'510 mA typ. (3.3 Vout model)
1'960 mA typ. (5 Vout model)
1'960 mA typ. (12 Vout model)
1'960 mA typ. (15 Vout model)
1'960 mA typ. (12 / -12 Vout model)
1'960 mA typ. (15 / -15 Vout model)
755 mA typ. (3.3 Vout model)
970 mA typ. (5 Vout model)
970 mA typ. (12 Vout model)
970 mA typ. (15 Vout model)
970 mA typ. (12 / -12 Vout model)
970 mA typ. (15 / -15 Vout model)
375 mA typ. (3.3 Vout model)
485 mA typ. (5 Vout model)
485 mA typ. (12 Vout model)
485 mA typ. (15 Vout model)
485 mA typ. (12 / -12 Vout model)
485 mA typ. (15 / -15 Vout model)
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
7.5 VDC min. / 8 VDC typ. / 8.8 VDC max.
15.5 VDC min. / 16 VDC typ. / 17.5 VDC max.
32.5 VDC min. / 33 VDC typ. / 35.5 VDC max.
30 mAp-p typ.
12 Vin models: 4'000 mA (slow blow)
24 Vin models: 2'000 mA (slow blow)
48 Vin models: 1'250 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Input Filter
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
single output models:
dual output models:
single output models:
dual output models:
dual output models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
–10% to +20% (24 Vout models)
±10% (other models)
(single output models only)
(By external trim resistor)
www.tracopower.com/overview/thn20
Output power must not exceed rated power!
±1% max.
0.2% max.
0.5% max.
0.2% max.
1% max. (Output 1)
1% max. (Output 2)
5% max.
75 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
75 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
75 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
75 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
100 / 100 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
100 / 100 mVp-p typ. (w/ 1 µF X7R || 10 µF TC)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
THN 20 Series, 20 Watt
Capacitive Load
- single output
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- dual output
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
7'000 µF max.
5'000 µF max.
850 µF max.
700 µF max.
500 / 500 µF max.
350 / 350 µF max.
Not required
±0.02 %/K max.
30 ms max.
Continuous, Automatic recovery
110 - 190% of Iout max.
150% typ. of Iout max.
112 - 164% of Vout nom.
250 µs typ. (25% Load Step)
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/thn20
PD 2
OVC I
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
External filter proposal:
Air:
Contact:
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/thn20
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
220 µF, 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
Power Derating
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
95% max. (non condensing)
–40°C to +75°C
–40°C to +85°C (with Heat Sink)
+105°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/thn20
Natural convection (20 LFM)
On: 3.0 to 15 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2 mA typ.
-0.5 to 1.0 mA
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
THN 20 Series, 20 Watt
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
5'000 m max.
275 kHz typ. (PWM) (±10%, 3.3 & 5 Vout model)
330 kHz typ. (PWM) (±10%, other models)
Functional Insulation
1'600 VDC
1'000 VDC
1'000 VDC
1'000 MΩ min.
1'000 pF max.
1'400'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
MIL-STD-810F
Copper, Nickel plated
Non-conductive FR4 (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
1" x 1"
Lead-Free Wave Soldering
265°C / 10 s max.
15 g
17.6 K/W typ.
14.8 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
47872c3c-f3a0-4ad5-ab75-2fa773c171c1
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thn20
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
THN 20 Series, 20 Watt
Outline Dimensions
7.62
5.08
(0.3)
(0.2)
1
5.6
9.9
2.5
10.16
(0.22)
(0.39)
(0.1)
(0.4)
3
2.5
4
5
(0.1)
Bottom view
(1.0)
2
25.4
(0.8)
20.32
6
Pinout
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
+Vout
+Vout
4
Trim
Common
5
–Vout
–Vout
6
Remote On/Off
Remote On/Off
10.16
(0.4)
25.4
(1.0)
Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)
Pin pitch tolerances ±0.25 (±0.01)
Pin diameter Ø 1.0 (0.04)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5